ACCUPAR LP-80 Tech Specs
Request a quote

Technical Specifications

Measurement Specifications
Probe PAR sensors
Range: 0.0000 – 2500.0000 μmol/(m2s)
Resolution: 1.0000 μmol/(m2s)
External PAR sensor
Range: 0 to 4,000 μmol/(m2s) (full sunlight ~2,000 μmol/[m2s])
Resolution: 1.0000 μmol/(m2s)
Accuracy: ±5.0 %
Unattended logging interval
Between 1 and 60 min (user selectable)
Physical Specifications
Computer interface
Locking 5-pin sealed circular connector to RS-232 cable
Controller
Length: 15.8000 cm (6.20 in)
Width: 9.5000 cm (3.75 in)
Height: 3.3000 cm (1.30 in)
Weight: 0.5500 kg  (1.21 lb) with batteries
External PAR sensor
Locking 5-pin sealed circular connector on 5-m cable
External sensor dimensions
Diameter: 24.0000 mm (0.94 in)
Height: 27.0000 mm (1.06 in)
Probe dimensions
Length: 86.5000 cm (34.06 in)
Width: 19.0000 mm (0.75 in)
Height: 9.5000 mm (0.38 in)
Probe sensors
Number: 80
Type: Photosynthetically active radiation sensor
External sensor
Number: 1
Type: Apogee SQ110 photosynthetically active radiation sensor
Data storage
1 MB flash memory
Operating Temperature Range
Minimum: 0 °C
Maximum: 50 °C
Operating relative humidity range
Minimum: 0 %
Maximum: 100 %
Power
4 AA batteries, included
Other
Compliance
Manufactured under ISO 9001:2015
EM ISO/IEC 17050:2010 (CE Mark)
GSA