What are some tips for a good ATMOS 41 installation?
  1. Location:  Make sure the location you choose will give you answers to the questions that you want answered.  If you’re looking for general weather monitoring, make sure the location is far (at least 3X height of tallest obstruction) from any obstructions to wind.  Make sure the vegetation is representative, and make sure the topographical location is representative.  Rooftops are pretty bad generally, as are deep valleys or hilltops.  If you’re looking for reference ET, you’ll want to deploy in the field with at least a few meters of crop on all sides of the installation. Also make sure that nothing is going to shade the solar radiation sensor.
  2. Height:  A lot of groups mount the ATMOS 41 at 2 m height, because this is the norm for reference evapotranspiration.  Others go higher for meteorological observations.  Some even deploy in the canopy for specialized research questions.  You can deploy easily at whatever height you want as long as you have the right mounting apparatus.
  3. Mounting apparatus:  The ATMOS 41 is designed to mount on a vertical rod (see the user manual and quickstart guide for exact dimensions).  It is often deployed on a vertical pole anchored by either guy wires or by a good-quality tripod.  Some even mount on T-posts, preferably with some guy wires to add stability.
  4. Level:  This is important for the ATMOS 41.  You need to have it level to within 2 degrees in both the X and Y.  There’s a bubble level underneath the rain funnel that you can see from below and use to get level.  The ATMOS 41 also outputs x and y level as standard outputs, so you can make sure you’re within 2 degrees of zero.  You’ll need to use the guy wires to pull the mounting apparatus level or add some shims to achieve proper level.
  5. Check the data flow before you leave the field:  Take a laptop (or handheld device if you’re using the ZL6 data logger) and the right software to make sure all the connections are good and that your data acquisition system is recording and/or transmitting data properly.  A good best practice is to set it all up in the lab or office first, troubleshoot any issues, and then go to the field.
  6. Always take a complete toolset:  You never really know what you’re going to need when troubleshooting unique situations.
  7. Tidy up the wires:  The single biggest failure mode for environmental sensors is the wiring. Zip tying extra wire to the mounting mast can keep it from getting snagged by animals or whipped around in windstorms and unplugged from the data logger.  Protecting the wiring in a cage or other container is great if you have the ability to do so.  Any of these things make the installation look more professional, which is an added bonus.
  8. For more info: Watch this webinar—7 Weather Station Installation Mistakes to Avoid

Related software downloads

ATMOS 41 Manual Manual PDF, 2.5MB
ATMOS 41 Quick Start Quickstart Guide PDF, 1.315MB
ATMOS 41 Integrator Guide Integrator Guide PDF, 1.0251MB
Bird Deterrent Installation Instructions Instructions PDF, 0.516MB
ATMOS 41 Cleaning Instructions Instructions URL, 0MB
Updating ATMOS 41 Firmware (Contact Support) Firmware URL, 0MB
Instructions for Swapping the ATMOS 41 RH Chip Instructions URL, 0MB
Rain Funnel and Pyranometer Replacement Instructions for ATMOS 41 Instructions PDF, 0.19MB
How to Check the ATMOS 41 Drip Counter Calibration Instructions URL, 0MB
Climavue 50 Shortcut CSI Example Program Instructions URL, 0MB
ATMOS 41 using M! CSI Example Program Instructions URL, 0MB
ATMOS 41 using C! CSI Example Program Instructions URL, 0MB
Anemometer Mast Assembly Instructions Manual PDF, 0.527MB
Get support

Need assistance?

Our experts are ready to help.