Popular Terms
Food
Applications
QA & QM
Production
R & D
Applied industries
Cured meats
Pet foods
Baked snack foods
Functional foods
Products
Product overview
Water activity meter
Moisture content analyzer
Vapor sorption analyzer
Platform
SKALA
MAT
Knowledge base
Customer Stories
Education guides
Expertise library
Market insights
Webinars
Podcast
Support
Services
Consumables
FAQs
Instrument training
Distributors
Downloads
Environment
Applications
Soil science
Weather monitoring
Hydrology
Plant science
Irrigation management
Soil thermal resistivity
Geotechnical engineering
Applied industries
Plant breeding
Ag weather networks
Soil infiltration testing
Sensor integrators
Products
Product overview
Data logger & telemetry
Weather
Soil moisture
Hydrology
Plant & canopy
Thermal properties
Laboratory instruments
Platform
ZENTRA Cloud
Knowledge base
Case studies
Education guides
Measurement insights
Webinars
Podcast
Office hours Q&A
Support
FAQs
Expertise library
Downloads
Services
Grants
Distributors
Horticulture
Applications
Cultivation
Processing
Applied cultivation
Indoor
Greenhouse
Products
Product overview
Telemetry
Substrate sensors
Climate sensors
Lab processing moisture
Platform
AROYA
Knowledge base
Case studies
Education guides
Office hours
Company
Corporate
History
Philosophy
Awards
News
Contact us
Impact
Corporate stories
Foundation
Sports
Career
Create the future
Working at METER
Jobs at METER Group
Jobs at METER Group AG
Jobs at ADDIUM
ATMOS 41 Tech Specs
Overview
Specifications
Support
Publications
Resources
Request a Quote
Technical Specifications
Measurement Specifications
Solar Radiation
Range:
0 – 1750 W/m
2
Resolution:
1 W/m
2
Accuracy:
± 5% of measurement typical
Precipitation
Range:
0 – 400 mm/h
Resolution:
0.017 mm
Accuracy:
± 5% of measurement from 0 to 50 mm/h
Relative Humidity (RH)
Range:
0 – 100 % RH (0.00 - 1.00)
Resolution:
0.1% RH
Accuracy:
Varies with temperature and humidity, ±1.5% RH typical.
See specification chart.
Hysteresis:
±0.80% RH, typical RH
Long-term Drift:
±0.25% RH/year, typical
Air Temperature
Range:
–50 to 60 °C
Resolution:
0.10 °C
Accuracy:
±0.60 °C
Humidity Sensor Temperature
Range:
–40 to 50 °C
Resolution:
0.10 °C
Accuracy:
± 1.0 °C
Vapor Pressure
Range:
0 – 47 kPa
Resolution:
0.01 kPa
Accuracy:
Varies with temperature and humidity, ±0.2 kPa typical below 40 °C.
See specification chart.
Barometric Pressure
Range:
1 – 120 kPa
Resolution:
0.01 kPa
Accuracy:
±0.05 kPa at 25 °C
Equilibration:
<10 ms
Long-term Drift:
< 0.1 kPa/year, typical
Horizontal Wind Speed
Range:
0–30 m/s
Resolution:
0.01 m/s
Accuracy:
The greater of 0.3 m/s or 3% of measurement
Wind Gust
Range:
0–30 m/s
Resolution:
0.01 m/s
Accuracy:
The greater of 0.3 m/s or 3% of measurement
Wind Direction
Range:
0 – 359 °
Resolution:
1 °
Accuracy:
±5 °
Tilt
Range:
–90° to 90°
Resolution:
0.1°
Accuracy:
±1 °
Lightning Strike Count
Range:
0 - 65,535 strikes
Resolution:
1 strike
Accuracy:
Variable with distance, >25% detection at <10km typical
Lightning Average Distance
Range:
0 – 40 km
Resolution:
3 km
Accuracy:
Variable
Communication Specifications
Output
SDI-12 communication
Data Logger Compatibility
METER ZL6 and EM60 data loggers or any data aquisition systems capable of switched 3.6- to 15.0-VDC excitation and SDI-12 communication
Physical Specifications
Dimensions
Diameter:
10.0 cm (3.9 in)
Height:
28 cm (11.0 in), includes rain gauge filter
Operating Temperature Range
Minimum:
–50 °C
Typical:
NA
Maximum:
60 °C
NOTE:
Barometric pressure and relative humidity sensors operate accurately at a minimum of –40 °C
Cable Length
5 m (standard)
75 m (maximum custom cable length for additional cost)
NOTE: Contact Customer Support if a nonstandard cable length is needed.
Cable Diameter
0.165 ±0.004 in (4.20 ±0.10 mm), with minimum jacket of 0.030 in (0.76 mm)
Connector Types
Stereo plug connector or stripped and tinned wires
Stereo Plug Connector Diameter
3.5-mm
Conductor Gauge
22-AWG / 24-AWG drain wire
Electrical and Timing Characteristics
Supply Voltage (VCC to GND)
Minimum:
3.6 VDC continuous
Typical:
NA
Maximum:
15.0 VDC continuous
NOTE:
The ATMOS 41 weather station must be continuously powered in order to work properly
NOTE: For the ATMOS 41 weather station to meet digital logic levels specified by SDI-12, it must be excited at 3.9 VDC or greater.
Digital Input Voltage (Logic High)
Minimum:
2.8 V
Typical:
3.0 V
Maximum:
5.5 V
Digital Input Voltage (Logic Low)
Minimum:
-0.3 V
Typical:
0.0 V
Maximum:
0.8 V
Digital Output Voltage (Logic High)
Minimum:
NA
Typical:
3.6 V
Maximum:
NA
NOTE:
For the ATMOS 41 weather station to meet digital logic levels specified by SDI-12, it must be excited at 3.9 VDC or greater.
Power Line Slew Rate
Minimum:
1.0 V/ms
Current Drain (During Measurement)
Minimum:
0.2 mA
Typical:
8.0 mA
Maximum:
33.0 mA
Current Drain (While Asleep)
Minimum:
0.2 mA
Typical:
0.3 mA
Maximum:
0.4 mA
Power Up Time (SDI Ready)—other commands
Minimum:
NA
Typical:
800 ms
Maximum:
NA
Power Up Time (SDI Ready)—aRx! commands
Minimum:
NA
Typical:
10 s
Maximum:
NA
Measurement Duration
Minimum:
NA
Typical:
110 ms
Maximum:
3000 ms
Other
Pyranometer Spectral Response
See graph in specification chart
Compliance
EM ISO/IEC 17050:2010 (CE Mark)
GSA