TEROS 31 Tech Specs

Technical Specifications

Measurement Specifications
Water Potential
Range: –85 to +50 kPa (up to –150 kPa during boiling retardation)
Resolution: ±0.0012 kPa
Accuracy: ±0.15 kPa
Temperature
Range: –30 to +60 °C
Resolution: ±0.01 °C
Accuracy: ±0.50 °C
NOTE: If the sensor unit is not buried, measured temperature may diverge from soil temperature.
Communication Specifications
Output
DDI serial
SDI-12 communication protocol
TensioLINKTM communication protocol
ModbusTM RTU communication protocol
Data Logger Compatibility
METER ZL6 and EM60 data loggers or any data acquisition system capable of 3.6- to 28.0-VDC excitation and SDI-12, Modbus RTU, or TensioLINK communication.
Physical Specifications
Dimensions
Width: 23.5 mm (0.93 in)
Height: 49.0 mm (1.93 in)
Depth: 17.5 mm (0.69 in)
Tensiometer Shaft Diameter
5 mm (0.19 in)
Tensiometer Shaft Length
2, 5, 7, 10, 15, or 20 cm
Materials
Ceramic: Al2O3, bubble point 500 kPa
Shaft: PMMA
Sensor Unit: PMMA and TPE
Operating Temperature Range
Minimum: 0.00 °C
Maximum: 50.00 °C
Cable Length
1.5 m
Cable Diameter
3.0 mm (0.12 in)
Connector Types
4-pin stereo plug connector
Stereo Plug Connector Diameter
3.5 mm
Conductor Gauge
31 AWG drain wire
Electrical and Timing Characteristics
Supply Voltage (VCC to GND)
Minimum: 3.6 VDC
Typical: 12.0 VDC
Maximum: 28.0 VDC
Digital Input Voltage (Logic High)
Minimum: 1.6 V
Typical: 3.3 V
Maximum: 5.0 V
Digital Input Voltage (Logic Low)
Minimum: -0.3 V
Typical: 0.0 V
Maximum: 0.9 V
Digital Output Voltage (Logic High)
Typical: 3.6 V
Power Line Slew Rate
Minimum: 1.0 V/ms
Current Drain (During Measurement)
Minimum: 18.0 mA
Typical: 25.0 mA
Maximum: 30.0 mA
Current Drain (While Asleep)
Minimum: 0.03 mA
Typical: 0.05 mA
Maximum: 0.90 mA
Power Up Time (DDI Serial)
Minimum: 125 ms
Typical: 130 ms
Maximum: 150 ms
Power Up Time (SDI-12)
Minimum: 125 ms
Typical: 130 ms
Maximum: 150 ms
Power Up Time (SDI-12, DDI Serial Disabled)
Minimum: 125 ms
Typical: 130 ms
Maximum: 150 ms
Measurement Duration
Minimum: 60 ms
Typical: 65 ms
Maximum: 70 ms
Other
BARO Module
When using the METER tensiometers TEROS 31 and TEROS 32 in combination with a non-METER data logger, a highly accurate barometric compensation is needed to get the most precise soil water potential measurement. The BARO Module can be used as a stand-alone sensor for measuring atmospheric pressure at a measuring site. It is also available with different connectors, so the BARO Module can be connected directly in between a tensiometer and a data logger. BARO Module can also act as a digital/analog converter to connect a tensiometer with serial output to a data logger with analog input channels. The logger obtains a barometric compensated analog matric potential signal. The BARO Module can be used for varied logger communications: SDI-12, Modbus, tensioLINK, analog voltage signal.
Compliance
EM ISO/IEC 17050:2010 (CE Mark)
GSA
ACCUPAR LP-80
ATMOS 14
ATMOS 22
ATMOS 41
ATMOS 41W
Drain Gauge G3 Lysimeter
ECH2O 10HS
ECH2O EC-5
HYDROS 21
HYPROP 2
KSAT
MINI DISK INFILTROMETER
PARIO
PHYTOS 31
SATURO
SC-1 Leaf Porometer
TEMPOS
TEROS 06
TEROS 10
TEROS 11
TEROS 12
TEROS 21
TEROS 31
TEROS 32
TEROS 51
TEROS 54
TEROS Borehole Installation Tool
VAPOR SORPTION ANALYZER
WP4C
ZL6
ZL6 Basic
ZL6 Pro
ZENTRA Cloud
Varios
Other

How can we contact you?

,
Yes
No

Privacy Policy Agreement

1
Send