TM
METER Legacy Pore Water Samplers

METER Legacy Pore Water Samplers

SK20 Suction Cup

  • Get Pricing
  • Picture

  • Description

    The SK20 uses ceramic cups made from Al203 sintered material which allows sampling and analysis for nitrate and common organic and inorganic substances.

    Applications

    • Continuous/discontinuous extraction
    • Nitrate, chloride, sulphate, calcium, sodium, ammonium, phosphate

    Benefits

    • Very low dead volume
    • Shaft and cup exchangeable
    • pH range of 4 to 9

    Limits

    • Not suitable for heavy metals
  • Specifications

     

    SHAFTØ 2 cm; Acrylic
    POROUS CERAMICØ 2 cm; length 6 cm
    BUBBLE POINT-100 kPa
    SUCTION TUBEPE; Ø 0.16 cm x Ø 0.28 cm
    PROTECTIVE TUBEPVC, Ø 1.1 cm
    ACHIEVABLE SAMPLE AMOUNTSMaximum: in free water and with a vacuum of -50 kPa approximately 5 mL per 10 minutes.

    Minimum: in sandy loam soil with a vacuum of -50 kPa approximately 5 mL per hour.

    COMPARISONS

    PORE WATER SAMPLERSK20/SKS20 (Internal Shaft Storage)SIC20/SICS20 (Internal Shaft Storage)SPE20/SPES20 (Internal Shaft Storage)
    SUCTION CUP MATERIALAluminum Oxide CeramicSilicon CarbidePorous PE-Nylon Cup
    CHEMICAL SUITABILITY
    • Anions ( Nitrate, Sulphate, Phosphate, Chloride)
    SuitableSuitableSuitable
    • Cations (Calcium, Potassium, Sodium Ammonium)
    Limited SuitabilitySuitableSuitable after conditioning and sufficient forerun for flushing.
    • Metals (Aluminum, Copper, Chromium, Iron, Magnesia, Nickel)
    Not SuitableSuitableSuitable
    • Heavy Metals (Cadmium, Lead)
    Not SuitableLimited SuitabilitySuitable
    *See Chemical Suitability Chart for more information on chemical suitability.
    BUBBLE POINT100 kPa90 kPa100 kPa (PE cover only allows water flow up to 20 kPa)
  • Comparisons
    PORE WATER SAMPLERSK20/SKS20 (Internal Shaft Storage)SIC20/SICS20 (Internal Shaft Storage)SPE20/SPES20 (Internal Shaft Storage)
    SUCTION CUP MATERIALAluminum Oxide CeramicSilicon CarbidePorous PE-Nylon Cup
    CHEMICAL SUITABILITY
    • Anions ( Nitrate, Sulphate, Phosphate, Chloride)
    SuitableSuitableSuitable
    • Cations (Calcium, Potassium, Sodium Ammonium)
    Limited SuitabilitySuitableSuitable after conditioning and sufficient forerun for flushing.
    • Metals (Aluminum, Copper, Chromium, Iron, Magnesia, Nickel)
    Not SuitableSuitableSuitable
    • Heavy Metals (Cadmium, Lead)
    Not SuitableLimited SuitabilitySuitable
    *See Chemical Suitability Chart for more information on chemical suitability.
    BUBBLE POINT100 kPa90 kPa100 kPa (PE cover only allows water flow up to 20 kPa)
  • Accessories

    Auger kits for pore water samplers and tensiometer

    The cutting edge of the auger has a tapered tip similar to the shape of a Tensiometer or pore water sampler.  Thus, the bore hole is large enough to insert the shaft, but the cup will have a tight and perfect fit to the soil.

    The not recommendable slurrying of the cup with quartz clay can be avoided.

    A divisible auger set includes:

    • Cutting edge with tapered tip
    • Handle with hammering head

    Parts have threaded connection and can be extended with one or more 100 cm extension rods.

    Benefits

    • Simplifies installation of shafts
    • Avoids slurrying
    • Multipart – divisible – extendable
    TB-20TB-25
    Dimensions:
    • Cutting Edge
    22 mm dia. x 50 cm26 mm dia. x 50 cm
    • Tip
    20 mm dia. x 5.6 cm24 mm dia. x 5.6 cm
    • Total length
    1.25 m1.5 m
    • For shafts with
    20 mm dia.24 mm dia.
    Part no.TB-20/125TB-25/150
    Extension rod Part no.TBE-100

     

    Sampling bottles and storage box

    Soil water sampling bottles made of Duran glass, available in three sizes.

    Benefits

    • Implosion proof
    • Plastic coating as chip guard
    • Silicon rubber gasket with two connectors
    • Accessory: Clip for upright attachment on walls
    • In the sampling bottle box up to 6 sampling bottles can be stored
    • The lid is covered with isolating material.
    • Latches shut the box securely.
    • The suction tubes are led through sealed fittings on the side of the box.

    Size: 40 cm x 30 cm x 28 cm

    Material: PVC

    ItemPart No.
    500 mL bottleSF-500
    1000 mL bottleSF-1000
    2000 mL bottleSF-2000
    Wall clipSF-CLIP
    Box with lidSF-Box
  • Manuals and Software
  • Pore solution video

     

SPE20 Suction Cup

  • Get pricing
  • Picture

  • Description

    The SPE20 contains a specialized membrane specifically designed for tough applications such as sampling heavy metals and where porous ceramics are inappropriate.

    Applications

    • For detection of herbicide, pesticide, and heavy metals

    Benefits

    • Only materials with sample contact are nylon and polyethylene
    • Low sorption

     Limits

    • Bubble point is 100 kPa, but the porous PE cover allows water to flow only up to 20 kPa
  • Specifications
    SHAFTØ 2 cm; Acrylic
    POROUS CERAMICØ 2 cm; length 6 cm
    BUBBLE POINT-100 kPa (only allows water flow up to -20 kPa)
    SUCTION TUBEPE; Ø 0.16 cm x Ø 0.28 cm
    PROTECTIVE TUBEPVC, Ø 1.1 cm
    ACHIEVABLE SAMPLE AMOUNTSMaximum: in free water and with a vacuum of -50 kPa approximately 5 mL per 10 minutes.

    Minimum: in sandy loam soil with a vacuum of -50 kPa approximately 5 mL per hour.

    COMPARISONS

    PORE WATER SAMPLERSK20/SKS20 (Internal Shaft Storage)SIC20/SICS20 (Internal Shaft Storage)SPE20/SPES20 (Internal Shaft Storage)
    SUCTION CUP MATERIALAluminum Oxide CeramicSilicon CarbidePorous PE-Nylon Cup
    CHEMICAL SUITABILITY
    • Anions ( Nitrate, Sulphate, Phosphate, Chloride)
    SuitableSuitableSuitable
    • Cations (Calcium, Potassium, Sodium Ammonium)
    Limited SuitabilitySuitableSuitable after conditioning and sufficient forerun for flushing.
    • Metals (Aluminum, Copper, Chromium, Iron, Magnesia, Nickel)
    Not SuitableSuitableSuitable
    • Heavy Metals (Cadmium, Lead)
    Not SuitableLimited SuitabilitySuitable
    *See Chemical Suitability Chart for more information on chemical suitability.
    BUBBLE POINT100 kPa90 kPa100 kPa (PE cover only allows water flow up to 20 kPa)
  • Comparisons
    PORE WATER SAMPLERSK20/SKS20 (Internal Shaft Storage)SIC20/SICS20 (Internal Shaft Storage)SPE20/SPES20 (Internal Shaft Storage)
    SUCTION CUP MATERIALAluminum Oxide CeramicSilicon CarbidePorous PE-Nylon Cup
    CHEMICAL SUITABILITY
    • Anions ( Nitrate, Sulphate, Phosphate, Chloride)
    SuitableSuitableSuitable
    • Cations (Calcium, Potassium, Sodium Ammonium)
    Limited SuitabilitySuitableSuitable after conditioning and sufficient forerun for flushing.
    • Metals (Aluminum, Copper, Chromium, Iron, Magnesia, Nickel)
    Not SuitableSuitableSuitable
    • Heavy Metals (Cadmium, Lead)
    Not SuitableLimited SuitabilitySuitable
    *See Chemical Suitability Chart for more information on chemical suitability.
    BUBBLE POINT100 kPa90 kPa100 kPa (PE cover only allows water flow up to 20 kPa)
  • Accessories

    Auger kits for pore water samplers and tensiometer

    The cutting edge of the auger has a tapered tip similar to the shape of a Tensiometer or pore water sampler.  Thus, the bore hole is large enough to insert the shaft, but the cup will have a tight and perfect fit to the soil.

    The not recommendable slurrying of the cup with quartz clay can be avoided.

    A divisible auger set includes:

    • Cutting edge with tapered tip
    • Handle with hammering head

    Parts have threaded connection and can be extended with one or more 100 cm extension rods.

    Benefits

    • Simplifies installation of shafts
    • Avoids slurrying
    • Multipart – divisible – extendable
    TB-20TB-25
    Dimensions:
    • Cutting edge
    22 mm dia. x 50 cm26 mm dia. x 50 cm
    • Tip
    20 mm dia. x 5.6 cm24 mm dia. x 5.6 cm
    • Total length
    1.25 m1.5 m
    • For shafts with
    20 mm dia.24 mm dia.
    Part no.TB-20/125TB-25/150
    Extension rod Part no.TBE-100

     

    Sampling bottles and storage box

    Soil water sampling bottles made of Duran glass, available in three sizes.

    Benefits

    • Implosion proof
    • Plastic coating as chip guard
    • Silicon rubber gasket with two connectors
    • Accessory: Clip for upright attachment on walls
    • In the sampling bottle box, up to 6 sampling bottles can be stored
    • The lid is covered with isolating material
    • Latches shut the box securely
    • The suction tubes are led through sealed fittings on the side of the box

    Size: 40 cm x 30 cm x 28 cm

    Material: PVC

    ItemPart No.
    500 mL bottleSF-500
    1000 mL bottleSF-1000
    2000 mL bottleSF-2000
    Wall clipSF-CLIP
    Box with lidSF-Box
  • Manuals and Software

SIC20 Suction Cup

  • Get Pricing
  • Picture

  • Description

    The SIC uses a specially designed Silicon Carbide (SiC) cup instead of a ceramic one.  SiC is sintered at 2500 °C and is chemically much more passive than ceramic or borosilicate. The bubble point is 90 kPa.

    Applications

    • Continuous/discontinuous extraction

    Benefits

    • High permeability
    • Low sorption
    • Very low dead volume
    • Shaft and cup exchangeable
  • Specifications

     

    SHAFTØ 2 cm; Acrylic
    SIC CUPØ 2 cm; Length 6 cm
    BUBBLE POINT-90 kPa
    SUCTION TUBETeflon; Ø 0.16 cm; Ø 0.28 cm
    PROTECTIVE TUBEPVC, Ø 1.1 cm
    ACHIEVABLE SAMPLE AMOUNTSMaximum: in free water and with a vacuum of -50 kPa approximately 5 mL per 10 minutes.

    Minimum: in sandy loam soil with a vacuum of -50 kPa approximately 5 mL per hour.

     

    COMPARISONS

    PORE WATER SAMPLERSK20/SKS20 (Internal Shaft Storage)SIC20/SICS20 (Internal Shaft Storage)SPE20/SPES20 (Internal Shaft Storage)
    SUCTION CUP MATERIALAluminum Oxide CeramicSilicon CarbidePorous PE-Nylon Cup
    CHEMICAL SUITABILITY
    • Anions ( Nitrate, Sulphate, Phosphate, Chloride)
    SuitableSuitableSuitable
    • Cations (Calcium, Potassium, Sodium Ammonium)
    Limited SuitabilitySuitableSuitable after conditioning and sufficient forerun for flushing.
    • Metals (Aluminum, Copper, Chromium, Iron, Magnesia, Nickel)
    Not SuitableSuitableSuitable
    • Heavy Metals (Cadmium, Lead)
    Not SuitableLimited SuitabilitySuitable
    *See Chemical Suitability Chart for more information on chemical suitability.
    BUBBLE POINT100 kPa90 kPa100 kPa (PE cover only allows water flow up to 20 kPa)
  • Comparisons
    PORE WATER SAMPLERSK20/SKS20 (Internal Shaft Storage)SIC20/SICS20 (Internal Shaft Storage)SPE20/SPES20 (Internal Shaft Storage)
    SUCTION CUP MATERIALAluminum Oxide CeramicSilicon CarbidePorous PE-Nylon Cup
    CHEMICAL SUITABILITY
    • Anions ( Nitrate, Sulphate, Phosphate, Chloride)
    SuitableSuitableSuitable
    • Cations (Calcium, Potassium, Sodium Ammonium)
    Limited SuitabilitySuitableSuitable after conditioning and sufficient forerun for flushing.
    • Metals (Aluminum, Copper, Chromium, Iron, Magnesia, Nickel)
    Not SuitableSuitableSuitable
    • Heavy Metals (Cadmium, Lead)
    Not SuitableLimited SuitabilitySuitable
    *See Chemical Suitability Chart for more information on chemical suitability.
    BUBBLE POINT100 kPa90 kPa100 kPa (PE cover only allows water flow up to 20 kPa)
  • Accessories

    Auger kits for pore water samplers and tensiometer

    The cutting edge of the auger has a tapered tip similar to the shape of a Tensiometer or pore water sampler.  Thus, the bore hole is large enough to insert the shaft, but the cup will have a tight and perfect fit to the soil.

    The not recommendable slurrying of the cup with quartz clay can be avoided.

    A divisible auger set includes:

    • Cutting edge with tapered tip
    • Handle with hammering head

    Parts have threaded connection and can be extended with one or more 100 cm extension rods.

    Benefits

    • Simplifies installation of shafts
    • Avoids slurrying
    • Multipart – divisible – extendable
    TB-20TB-25
    Dimensions:
    • Cutting edge
    22 mm dia. x 50 cm26 mm dia. x 50 cm
    • Tip
    20 mm dia. x 5.6 cm24 mm dia. x 5.6 cm
    • Total length
    1.25 m1.5 m
    • For shafts with
    20 mm dia.24 mm dia.
    Part no.TB-20/125TB-25/150
    Extension rod Part no.TBE-100

     

    Sampling bottles and storage box

    Soil water sampling bottles made of Duran glass, available in three sizes.

    Benefits

    • Implosion proof
    • Plastic coating as chip guard
    • Silicon rubber gasket with two connectors
    • Accessory: Clip for upright attachment on walls
    • In the sampling bottle box, up to 6 sampling bottles can be stored
    • The lid is covered with isolating material
    • Latches shut the box securely
    • The suction tubes are led through sealed fittings on the side of the box

    Size: 40 cm x 30 cm x 28 cm

    Material: PVC

    ItemPart No.
    500 mL bottleSF-500
    1000 mL bottleSF-1000
    2000 mL bottleSF-2000
    Wall clipSF-CLIP
    Box with lidSF-Box
  • Manuals and Software

SKS20/SPES20/SIC20 Suction Cups with Shaft Storage

  • Get pricing
  • Picture

  • Description

    The SKS20/SPES20/SICS20 allows for water and solute collection down to depths of 8 meters that could not normally be collected from other pore water samplers.  Available with all three sampling cup materials (Al203 Ceramic, Polyethylene Membrane, and Silicon Carbide).

    Applications

    Thanks to its unique design, the SKS20/SPES20/SICS20 collects the sampled solutions and stores them inside of the shaft, where they can later be collected by applying pressure to push the sampled solution up to a sampling bottle at the surface.  At these depths, water cannot be collected by applying suction because of cavitation.

    Benefits

    • Cost effective; sampling bottles are not needed
    • Extracted soil water is stored at soil temperature

    Limits

    • Chemical suitability limited to the chosen suction cup material
  • Specifications

     

    SHAFTØ 2.5 cm; PE
    POROUS CERAMICØ 2 cm; length 6 cm
    BUBBLE POINTAl203 Ceramic: -100 kPa; Silicon Carbide: -90 kPa; PE Membrane; -100 kPa (only allows water flow up to -20 kPa)
    SUCTION TUBEPE; Ø 0.2 cm x Ø 0.4 cm
    ACHIEVABLE SAMPLE AMOUNTSMaximum: in free water and with a vacuum of -50 kPa approximately 5 mL per 10 minutes.

    Minimum: in sandy loam soil with a vacuum of -50 kPa approximately 5 mL per hour.

     

    COMPARISONS

    PORE WATER SAMPLERSK20/SKS20 (Internal Shaft Storage)SIC20/SICS20 (Internal Shaft Storage)SPE20/SPES20 (Internal Shaft Storage)
    SUCTION CUP MATERIALAluminum Oxide CeramicSilicon CarbidePorous PE-Nylon Cup
    CHEMICAL SUITABILITY
    • Anions ( Nitrate, Sulphate, Phosphate, Chloride)
    SuitableSuitableSuitable
    • Cations (Calcium, Potassium, Sodium Ammonium)
    Limited SuitabilitySuitableSuitable after conditioning and sufficient forerun for flushing.
    • Metals (Aluminum, Copper, Chromium, Iron, Magnesia, Nickel)
    Not SuitableSuitableSuitable
    • Heavy Metals (Cadmium, Lead)
    Not SuitableLimited SuitabilitySuitable
    *See Chemical Suitability Chart for more information on chemical suitability.
    BUBBLE POINT100 kPa90 kPa100 kPa (PE cover only allows water flow up to 20 kPa)
  • Comparisons
    PORE WATER SAMPLERSK20/SKS20 (Internal Shaft Storage)SIC20/SICS20 (Internal Shaft Storage)SPE20/SPES20 (Internal Shaft Storage)
    SUCTION CUP MATERIALAluminum Oxide CeramicSilicon CarbidePorous PE-Nylon Cup
    CHEMICAL SUITABILITY
    • Anions ( Nitrate, Sulphate, Phosphate, Chloride)
    SuitableSuitableSuitable
    • Cations (Calcium, Potassium, Sodium Ammonium)
    Limited SuitabilitySuitableSuitable after conditioning and sufficient forerun for flushing.
    • Metals (Aluminum, Copper, Chromium, Iron, Magnesia, Nickel)
    Not SuitableSuitableSuitable
    • Heavy Metals (Cadmium, Lead)
    Not SuitableLimited SuitabilitySuitable
    *See Chemical Suitability Chart for more information on chemical suitability.
    BUBBLE POINT100 kPa90 kPa100 kPa (PE cover only allows water flow up to 20 kPa)
  • Accessories

    Auger kits for pore water samplers and tensiometer

    The cutting edge of the auger has a tapered tip similar to the shape of a Tensiometer or pore water sampler.  Thus, the bore hole is large enough to insert the shaft, but the cup will have a tight and perfect fit to the soil.

    The not recommendable slurrying of the cup with quartz clay can be avoided.

    A divisible auger set includes:

    • Cutting edge with tapered tip
    • Handle with hammering head

    Parts have threaded connection and can be extended with one or more 100 cm extension rods.

    Benefits

    • Simplifies installation of shafts
    • Avoids slurrying
    • Multipart – divisible – extendable
    TB-20TB-25
    Dimensions:
    • Cutting edge
    22 mm dia. x 50 cm26 mm dia. x 50 cm
    • Tip
    20 mm dia. x 5.6 cm24 mm dia. x 5.6 cm
    • Total length
    1.25 m1.5 m
    • For shafts with
    20 mm dia.24 mm dia.
    Part no.TB-20/125TB-25/150
    Extension rod Part no.TBE-100

     

    Sampling bottles and storage box

    Soil water sampling bottles made of Duran glass, available in three sizes.

    Benefits

    • Implosion proof
    • Plastic coating as chip guard
    • Silicon rubber gasket with two connectors
    • Accessory: Clip for upright attachment on walls
    • In the sampling bottle box, up to 6 sampling bottles can be stored
    • The lid is covered with isolating material
    • Latches shut the box securely
    • The suction tubes are led through sealed fittings on the side of the box

    Size: 40 cm x 30 cm x 28 cm

    Material: PVC

    ItemPart No.
    500 mL bottleSF-500
    1000 mL bottleSF-1000
    2000 mL bottleSF-2000
    Wall clipSF-CLIP
    Box with lidSF-Box
  • Manuals and Software

It’s not immortal, but almost

Specifically designed for field-use, the T4 tensiometer ceramic and shaft are engineered to be virtually indestructible when it comes to harsh weather. Plus, it can be filled without ever …

Particle-size analysis, automated